2010-09-10 11:40:31
28.00€ +0.61 %


Home > Technologies > Lithium > Li-SOCl2 > LSH cell range


Lithium-thionyl chloride (Li-SOCl2) - LSH cell range

Non rechargeable battery

Download literature
Stockcheck
Click here to check this product's inventory (North america only)

The Saft LSH cylindrical primary lithium cells are based on Lithium-Thionyl chloride (Li-SOCl2) chemistry and feature high surface area spiral electrodes for maximum current capability.

They are designed for applications requiring continuous currents in the 0.1-1.8 A range, with superimposed pulses as high as 4 A.

Construction features

  • spiral electrodes
  • stainless steel container
  • hermetic and sturdy glass-to-metal sealing
  • built-in safety vents
  • individual cells with 5.5 A non-resettable fuse
  • available as individual batteries (size 1/3 C to D; with or without tabs) or multi-cell battery packs

 

Main applications

  • utility metering
  • automated meter reading
  • alarms and security wireless devices
  • mobile asset tracking
  • GPS
  • emergency location transmitters beacons (ELTs, EPIRBs)
  • professional electronics
  • military radiocommunication
  • sonobuoys
  • oil exploration
  • automotive telematics
  • telemetry

 

Benefits

  •  High operating voltage, stable during most of the application lifetime
  • Good pulse capability
  • Wide operating temperature range  (-60°C to +70°C),  +120°C for some cell versions
  • Good resistance to passivation 
  • Non-flammable (and non-pressurized at ambient temperature),  inorganic (but corrosive) electrolyte
  • Less than 3% capacity loss per year, during storage at ambient temperature before use
  • Performance independent from cell orientation
  • Up to 25 years of mass production experience
  • Compliant with the European directive RoHS
  • Good safety records
Download literature
  • Data sheet
  • Market brochures
  • Selector guide
  • Transport certificates
  • MSDS
Technical characteristics
  • 3.67 V open circuit voltage
  • Operating voltage (depending on conditions) typically above 3 V
  • Underwriters Laboratories (UL) Component  Recognition (File number MH 12609)
  • Compliance with IEC 60086-4 

 

  LSH 26180 LSH 14 LSH 14 "light" LSH 20 LSH 20HTS
Cell type constuction 1/3 C C C D D
Open Circuit Voltage 3.67 V 3.67 V 3.67 V 3.67 V 3.67 V
Nominal Voltage 3.6 V 3.6 V 3.6 V 3.6 V 3.6 V
Nominal capacity (drain) 1.2 Ah (10 mA) 5.8 Ah (15 mA) 3.6 Ah (15 mA) 13.0 Ah (15 mA) 11.0 Ah (100 mA)
Max. recom. Cont. Current 0.4 A 1.3 A 1.3 A 1.8 A 1 A
Operating temp. range -60/+85°C * -60/+85°C * -60/+85°C * -60/+85°C * -60/+85°C**
Outside diameter max 26.2 mm 26.0 mm 26.0 mm 33.4 mm 33.4 mm
Length max 18.6 mm 50.4 mm 50.4 mm 61.6 mm 61.6 mm
Weight 24 g 51 g 51 g 100 g 100g
Transport Non-restricted Restricted
(Class 9)
Non-restricted Restricted
(Class 9)
Restricted
(Class 9)

 

  LSH 20-150        
Cell type constuction D        
Open Circuit Voltage 3.67 V        
Nominal Voltage 3.6 V        
Nominal capacity (drain) 14.0 Ah (300 mA)        
Max. recom. Cont. Current Consult Saft        
Operating temp. range -40/+ 150°C        
Outside diameter max 32.05 mm        
Length max 61.7 mm        
Weight 104.5 g        
Transport Restricted
(Class 9)
       

Individual cells fitted with non-resettable 5 Amp fuse protection
* cells leakproof up to 120°C.

** At +85°C, to maintain cell heating within safe limits. Battery packs may imply lower level of maximum current and may request specific thermal protection. Consult Saft.

Data in this page is subject to change without notice and becomes contractual only after written confirmation by Saft.